YG(B)233D Paper Diaper Penetration Tester
Category:
keywords:
Pilling& Snaaging testing instrument
YG(B)233D Paper Diaper Penetration Tester
Paper Diaper Penetration Tester
Product Description
【Scope of Application】:
Used for the determination of the absorption speed, backflow volume, and permeation volume of paper diapers, etc., to measure their permeation performance.
[Related Standards]:
Appendix A of GB/T28004.1-2021, GB/T28004.2-2021, etc.
【Technical Characteristics】:
1. 1+X workstation design, flexible and applicable for testing samples of different specifications, convenient and efficient;
2. Large screen color touch screen display, user-friendly interface design for easy operation;
3. Sample fixtures adopt high-strength transparent materials with distributed force design, resistant to impact, corrosion and deformation;
4. Sample holders, liquid addition modules, etc. can be quickly replaced, effectively improving testing efficiency;
5. High-precision peristaltic pump for liquid addition, liquid addition rate and volume can be set, meeting different testing requirements;
6. Control components use STMicroelectronics 32-bit processor, can be connected to a computer and support data export and printing;
7. Built-in electrodes for automatically determining absorption speed, improving testing automation and test efficiency;
8. Equipped with an online electronic balance, can automatically read the program and assist in calculating test results;
9. Equipped with a liquid storage tank heating device, heating the experimental physiological saline to the required temperature.
【Technical Specifications】:
1. Flow rate range: (480 ± 5) mL/min (for infants and children), (750 ± 5) mL/min (for adults). It can be set, with an accuracy of ± 2 mL.
2. Pressurization and liquid addition module:
| Baby | W | (80±1)mm(M1) | (85±1)mm(M2) | (95±1)mm(M3) |
| L | (100±1)mm(M1) | (108±1)mm(M2) | (125±1)mm(M3) | |
| Adult | W | (70±1)mm(M1) | (95±1)mm(M2) | / |
| L | (170±1)mm(M1) | (170±1)mm(M2) | / |
3. Pressurization Pressure:2.0±0.2kPa、4.0±0.2kPa。
4、Sample base:
| Baby |
U-shaped sample base | W | 122±1mm(B1) | 135±1mm(B2) | 152±1mm(B3) |
| L | 125±1mm(B1) | 136±1mm(B2) | 154±1mm(B3) | ||
| Adult | Arc-shaped sample holder | 319mm*200mm(L*W) | |||
5. Heating range of the test solution: from room temperature to 50℃
6. Weighing balance: range 300g, accuracy 0.01g.
7. Time range: 0.00 to 9999.99 seconds, accuracy: ±0.01 seconds.
8. Dimensions approximately (excluding the balance and water bath pot): 520mm × 670mm × 900mm (L × W × H).
9. Power specification: AC 220V ± 10%, 50Hz, 2000W
10. Weight (only the instrument): approximately 95kg